Radio-tv Christiaanse Burgh-Haamstede

Multimeter Putec M890G

Multimeter

Multimeter Putec M890G
19.99 *Prijzen zijn inclusief btw
ArtikelcodePutec M890
Technical specifications
Note: The following values can differ slightly from model to model; consult your user manual for your meter's technical specifications.
DC Volts
Input impedance: 10MO
Range
Resolution
Accuracy
200mV
0.1mV
± 0.5% of rdg ± -1 digit
2V
1mV
± 0.5% of rdg ± 1 digit
20V
10mV
± 0.5% of rdg ± 1 digit
200V
100mV
± 0.5% of rdg ± 1 digit
1000V
1V
± 0.8% of rdg ± 2 digits
AC Volts
Input impedance: 10MO at all ranges.
Frequency Response: 40Hz - 200Hz (40Hz-100Hz for the 200V and 700V range).
Overload Protection:
- 200mV: max. 15 seconds at a voltage of 300V AC
- all other ranges: 750V AC or 1000V DC.
Range
Resolution
Accuracy
200 mV
0.1mV
± 1.2% of rdg ± 3 digits
2V
1 mV
± 0.8% of rdg ± 3 digits
20V
10 mV
± 0.8% of rdg ± 3 digits
200V
100 mV
± 0.8% of rdg ± 3 digits
700V
1V
± 1.2% of rdg ± 3 digits
DC Amps
Overload protection: 0.2A / 250V fuse
The 20A range is unfused. Maximum input current: 20 A for 15 seconds.
Range
Resolution
Accuracy
2mA
1µA
± 0.8% of rdg ± 1 digit
20mA
10µA
± 0.8% of rdg ± 1 digit
200mA
100µA
±1.2% of rdg ± 1 digit
20A
10mA
± 2.0% of rdg ± 5 digits
AC Amps
Overload protection: 0.2A / 250V fuse
The 20A range is unfused. Maximum input current: 20 A for 15 seconds.
Range
Resolution
Accuracy
200mA
100µA
± 2.0% of rdg ± 3 digits
20A
10mA
± 3.0% of rdg ± 7 digits
Note: some models have a 20mA range with a resolution of 10 µA and ±1,2% ± 3 digits accuracy.
Resistance (Ohms)
Range
Resolution
Accuracy
200O
0,1O
± 0.8% of rdg ± 3 digits
2kO
1O
± 0.8% of rdg ± 1 digits
20 kO
10O
± 0.8% of rdg ± 1 digits
200 kO
100O
± 0.8% of rdg ± 1 digits
2MO
1kO
± 0.8% of rdg ± 1 digits
20MO
10kO
± 1% of rdg ± 2 digits
200MO (a few models only)
100 kO
± 5% of rdg ± 10 digits
Capacitance
Range
Resolution
Accuracy
2000pF
1pF
± 2.5% of rdg ± 5 digits
20nF
10pF
± 2.5% of rdg ± 5 digits
200nF
100pF
± 2.5% of rdg ± 5 digits
2µF
1nF
± 2.5% of rdg ± 5 digits
20µF
10nF
± 2.5% of rdg ± 5 digits
Frequency
Range
Resolution
Accuracy
20kHz
10Hz
± 1% of rdg ± 1 digits
Transistor hFE test
hFE range:0-1000
Ib: ~10µA
Uce: ~ 2,8V.
Temperature
"K" type thermocouple
Range
Resolution
Accuracy
-50°C - 400°C
1°C
± 0.75% of rdg ± 3 digits
400°C-1000°C
1°C
± 1.5% of rdg ± 15 digits
Diode and conductivity test
Diode test forward current: ~ 1mA.
Voltage: ~ 2.8V
The built-in buzzer will sound, if the resistance under test is less than about 30 ohms.